OPERATION MANUAL Frymaster, L.L.C., 8700 Line Avenue Shreveport, LA 71106 TEL 318-865-1711 FAX 318-868-5
10 B. TEST POWER TO FRYER INTERFACE BOARD 1. Switch the HP690 POWER switch (11) to ON. 2. RELAY POWER indicator (3) should illuminate. 3. Tu
11 F. TEST PROBE FAILURE MALFUNCTION 1. Turn on FTB-350A POWER switch (10). 2. Set FTB-350A PROBE switch (7) to SHORT. (a) RELAY POWER indicator
12 F3000 TEST PROCEDURE FOR PITCO FRYERS (18WKS FULL, SG18 FULL, SSH75 FULL, SG6H FULL, 14WKS FULL, 7WKS FULL, 7-2WKS SPLIT, E18WKS FULL, SE18 17 KW F
THIS PAGE INTENTIONALLY LEFT BLANK
Frymaster, L.L.C Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Suppor
2 TABLE OF CONTENTS
3 INTRODUCTION The FTB-350A Test Box is a tester designed to test the F3000 Frymaster cooking controller for correct operating and controlling functi
4 PARTS LIST Item Part Number Description 826-2978 Kit, FTB350A, 120V/24V F3000 Test Box (Includes cable and transformer assembly.) 1 108-3
5 CONTROL PANEL 1. Stratify Indicator On during stratify on HP fryers. 7. Right Probe/Thermistor Switch Simulates Temperature 2. Left Heat Indicat
6 F3000 TEST PROCEDURE FOR LEGACY FRYMASTER FRYERS (KJ3, 118G, H55, MJ45, 118E/RE80 and FPRE114/117) Ensure the controller is set to LEGACY-FRYMASTER
7 D. TEST CONTROLLING FUNCTION 1. Press controller ON/OFF switch to ON (set point = 340°F/171°C). 2. Set FTB-350A PROBE switches (6 & 7) to VAR
8 F3000 TEST PROCEDURE FOR HENNY PENNY PRESSURE FRYERS (HP580 and HP590) Ensure the controller is set to HENNY PENNY 580/590/290 FULL using code 7628
9 n) Leave 2 FLEX at 0. Press the right (X) arrow. o) Leave 2 PRESSURE SOLENOID to OPEN. Press the right (X) arrow. p) Leave :00 at 3 TIME. Press